Fire safety statements, NSW

Annual fire safety statements for NSW commercial landlords

What the statement is, who must give it, the 12 month cycle and the 3 month assessment window, and what a commercial property manager does each year to keep it current.

  • NSW Licence 10103554

What an annual fire safety statement is

An annual fire safety statement is a statement issued by or on behalf of the building owner that each essential fire safety measure has been assessed by an accredited practitioner (fire safety) and that the building has been inspected (section 88(1)). The owner must give it to the council within 12 months of the previous one (section 89(1), (2)), send a copy with the current fire safety schedule to the Fire Commissioner, and display both prominently in the building (section 89(4)). The assessment and inspection must be carried out in the 3 months before the statement is issued (section 88(2)). A solicitor should confirm how the Regulation applies to a particular building.

Single storey medical centre at dusk with lit entrance
  • s 87
  • s 88(1)
  • Dictionary

What is an annual fire safety statement?

It is a statement issued by or on behalf of the owner of a building that two things are true. First, each essential fire safety measure listed in the statement has been assessed by an accredited practitioner (fire safety) as capable of performing to a standard no less than the fire safety schedule specifies, or for an original measure, the standard it was designed and implemented to. Second, the building has been inspected by an accredited practitioner (fire safety) and was found to be in a condition that did not disclose grounds for a prosecution under Part 15 (section 88(1)).

The Part applies to all buildings other than class 1a and class 10 buildings and temporary structures (section 87). An accredited practitioner (fire safety) holds an accreditation under the Building and Development Certifiers Act 2018 that authorises the holder to act in that role (Dictionary). The source is the Environmental Planning and Assessment (Development Certification and Fire Safety) Regulation 2021 (NSW), Part 12.

  • s 88(1)
  • s 88(3)
  • s 89(1)
  • s 81(1)

Who is responsible for the statement, the landlord or the tenant?

The Regulation puts the duty on the owner of the building. The owner must give the statement to the council (section 89(1)) and may choose the person who carries out the assessment and inspection (section 88(3)). The owner also has a separate duty to maintain each essential fire safety measure (section 81(1)).

In a lease, the cost and the practical work can be allocated by its terms. A landlord can recover the cost as an outgoing only if the lease allows it. If it does, the outgoings calculator is a place to test how outgoings are shared. A solicitor should confirm who bears the obligation under a particular lease.

  • s 79(4)
  • s 81(1)
  • s 88(4)

Which fire safety measures does the statement cover?

The statement covers each essential fire safety measure for the building. Measures are specified in the building’s fire safety schedule, and a building with no schedule can still have original measures that apply (section 81(1)). The table of statutory fire safety measures in section 79(4) includes:

  • Automatic fire detection and alarm systems
  • Automatic fire suppression systems
  • Emergency lifts
  • Emergency lighting
  • Emergency warning and intercommunication systems
  • Exit signs
  • Fire dampers
  • Fire doors
  • Fire hose reel systems
  • Fire hydrant systems
  • Portable fire extinguishers
  • Smoke alarms and heat alarms
  • Standby power systems
  • Warning and operational signs

The practitioner must inspect and verify the performance of each measure being assessed (section 88(4)).

  • s 89(2)
  • s 88(2)
  • s 89(3)

How often is an annual fire safety statement due?

A statement must be given to the council within the later of two dates: 12 months after the previous statement was given to the council, or, if a fire safety certificate has been issued in the previous 12 months, 12 months after that certificate was issued (section 89(2)). The assessment and inspection must have been carried out in the 3 months before the statement is issued (section 88(2)).

The cycle runs from the last lodgement date, not from the calendar year, so a statement lodged early or late moves every later due date. Failing to give the statement in time is a separate offence for each week the failure continues (section 89(3)). The statement calendar below draws the dates from your last lodgement.

  • 12 monthsBetween statements given to the council
  • 3 monthsWindow for the assessment and inspection before issue
  • s 89(4)
  • s 89(1)

What happens after the statement is issued?

The statement is given to the council (section 89(1)). As soon as practicable after it is issued, the owner must also give a copy of the statement and a copy of the current fire safety schedule to the Fire Commissioner, and ensure copies of both are prominently displayed in the building (section 89(4)).

Keep the issued copy, proof of lodgement with the council, proof of the copy to the Fire Commissioner and a photograph of the display with the building record.

  • s 81(1)
  • s 89(1)
  • s 89(3)
  • s 89(4)(b)

Do penalties apply to a late or missing statement?

Penalties apply under the Regulation. Failing to give the statement to the council is an offence (section 89(1)), and failing to do so in time is a separate offence for each week the failure continues (section 89(3)). Failing to display the statement and schedule is an offence with its own maximum penalty (section 89(4)(b)), and so is failing to maintain essential fire safety measures (section 81(1)).

Maximum penalties are set in penalty units and are higher for a corporation than for an individual.

  • Property management

What does a commercial property manager do each year?

  1. Diary the date

    Set the due date from the last lodgement date, with reminders at six months, four months and one month before.

  2. Brief the practitioner

    Engage an accredited practitioner (fire safety), supply the fire safety schedule and the last report, and list any tenant works since the last assessment.

  3. Arrange access

    Notify tenants of inspection dates and arrange access to plant rooms and tenancies.

  4. Chase defects

    Take the practitioner’s defect list, get quotes, instruct repairs and track each item to closed.

  5. Lodge, send and display

    Issue the statement, give it to the council, send the copy and schedule to the Fire Commissioner and display both in the building.

  6. Keep the record

    File the statement, schedule, report, proof of lodgement and defect closure evidence, then reset the diary.

Blox runs this cycle as part of commercial property management.

Commercial precinct rooftops at dawn
  • Property management

Where do annual fire safety statements lapse?

After a change of owner or manager

The diary sits with the previous manager, and the new one inherits a building with no due date. Ask for the last statement, the fire safety schedule and the last practitioner report at handover, and diarise the date that week.

Defects left open

A statement says each measure was assessed as capable of performing to its standard. An open defect on a fire door, exit light or detector needs resolving before the statement is issued. The practitioner can advise what can be certified.

Tenant alterations

Tenant fit-out can add, move or remove doors, detectors, sprinkler heads and exit signs. Record each alteration, ask the tenant for the contractor’s documents and tell the practitioner before the assessment, so the statement matches the building as it now stands.

Tool

Statement calendar

Enter the date the last statement was given to the council. The page draws the next due date, the 3 month assessment window and the reminder points.

The date shown is an example. Replace it with your own. A certificate date only matters if it falls after the last statement.

Next statement due

Assessment and inspection window
Cycle starts Due

    Points A, B and D are suggested diary points, not requirements of the Regulation. The 3 month window follows section 88(2) for a statement issued on the due date. A solicitor should confirm the due date for a particular building.

    FAQ

    Fire safety statement questions landlords ask

    What is an annual fire safety statement?

    It is a statement issued by or on behalf of a building owner that each essential fire safety measure has been assessed as capable of performing to its standard and that the building has been inspected, both by an accredited practitioner (fire safety)., under section 88(1) of the Regulation.

    Who is responsible for the annual fire safety statement, the landlord or the tenant?

    The Regulation places the duty on the owner of the building (sections 88(1) and 89(1)). A lease can allocate the cost and the practical tasks, and a landlord can recover the cost as an outgoing only if the lease allows it. A solicitor should confirm the position under a particular lease.

    How often is an annual fire safety statement required?

    Each statement must be given to the council within 12 months of the previous one, or within 12 months of a fire safety certificate issued in the previous 12 months if that is later (section 89(2)). The assessment and inspection must be carried out in the 3 months before the statement is issued (section 88(2)).

    What happens if an annual fire safety statement is late?

    Failing to give the statement to the council in time is a separate offence for each week the failure continues (section 89(3)). Penalties apply under the Regulation and are higher for a corporation than for an individual. A solicitor should advise on a particular case, and the practitioner should be booked promptly.

    Commercial precinct rooftops at dawn

    Who keeps the fire safety diary?

    A managing agent can diarise each building’s due date, brief the practitioner and track defects to closure. Read about our commercial property management.

    Enquiry

    Ask about fire safety statements

    Send the property address and the date of the last statement, or ask a general question.

    Shopfront of a retail tenancy at street level

    This guide is general information about the Environmental Planning and Assessment (Development Certification and Fire Safety) Regulation 2021 (NSW), read in its in-force text. It is not legal advice. A solicitor should confirm how the Regulation applies to a particular building and lease.

    Call 02 8883 4559Ask a question